DESCRIPTION

DELTACOAT ESB is a high performance two components solvent based epoxy coating which is used in all kinds of manufacturing, storage and processing areas. The characteristics of these materials provide a surface that not only has greater durability but also a chemical resistant barrier to the substrate. DELTACOAT ESB can be applied on concrete/ cement based surface, mild steel, zinc, asbestos, wood, etc.

CHARACTERISTICS

  • Excellent adhesion
  • Excellent hardness
  • Good scratch resistance
  • Good chemical resistance
  • Gloss surface
  • Easily cleaned non skid surface
  • Suitable for damp substrate application

PHYSICAL PROPERTIES

No. Item Enamel Hardener
1 Colour Available on request Clear to yellow
2 Appearance Liquid Liquid
3 Viscosity (cps) 700 - 3000 15 – 30
4 Solid content (%) 70 – 80 % 20 – 30%
5 Specific Gravity 1,45 ± 0,05 0,85 – 0,95

PREPARATION AND APPLICATION

Surface Preparation :

Surface must be free oil, grease, water, and other contaminants that may inhibit bond.

Application :

Mix enamel and hardener for a minimum of 2 minutes thoroughly until the mix become homogeneous. Spread out the mix using roller or trowel to cover all the surface. Allow first coat to dry for approximately 2 hours. Second coat must be applied at a 900 angle to the first coat.

Pot life (at 250C) = 4 hours
Coverage = 4 m2/kg (2 coats), thickness = 100µm
Setting/curing
Do not allow water or chemicals on the coated surface for a minimum of 72 hours.

LIMITATIONS

Deltacoat ESB should not applied on the surface known to, or likely to suffer form, rising dampness, potential osmosis problems or have a relative humidity greater than 75%. If movement or cracking of the substrates takes place after application then reflective cracking of topping may occur. Ambient temperature when application is more than 100C.

CURING TIME (at 300C)

Pot Life 100 minutes
STT 4 hours
Initially hardness 9 hours
Fully cured after 3 days
(ambient temperature may have some effect on the curing time)

TECHNICAL DATA

Form Liquid (component A and B)
Viscoty Enamel 8580 cps
Viscoty Hardener 400 cps
Specific Gravity Mix 1.30 – 1.40
Shelf Life 1 year when unopened and stored in dry conditions
Packaging 4 kg set (Component A+B)
Comp. A (enamel) : 3 kg/can
Comp. B (hardener) : 1 kg/can

LIMITATIONS

Deltacoat ESB should not applied on the surface known to, or likely to suffer from, rising dampness, potential osmosis problems or have a relative humidity greater than 75%. If movement or cracking of the substrate takes place after application then reflective cracking of topping may occur. Ambient temperature when application is more than 100C.

HEALTH AND SAFETY

Deltacoat ESB range of products can cause skin irritations in persons with sensitive skin. Wear protective clothing like gloves, goggles and respiratory equipment, particularly in confined spaces. Ensure adequate ventilation and avoid inhalation of vapors. If splashed into the eyes, nose, mouth or throat, flush immediately with plenty of clean, warm water and seek medical attention without delay.

FIRE

Deltacoat ESB in non-flammable material.

Deltacoat ESF

High Gloss Solvent Free Epoxy Coating

DESCRIPTION

Deltacoat ESF is a two-component solvent free epoxy coating that suitable for coating of wallsystem. The cured film of Deltacoat ESF forms a hard, gloss and smooth layer with excellent adhesion to concrete substrate.

USES

Deltacoat ESF is recommended to areas where chemical resistance and aspects are required. Deltacoat ESF is recommended for use in floor of warehouses, industrial and food processing areas, kitchen, laboratory, engineering workshops, and car parks.

ADVANTAGES

Impervious seamless and jointless surface, easy to clean and maintain, hygienic, chemical resistance, excellent wear and abrasion resistance and have aesthetic state of art.

CONSUMPTION

Deltacoat ESF consumption is 0.25 – 0.3 kg/m2 for 175 micron thickness. Please kindly contact DELTACRETE to have appropriate technical assistance for the recommended thickness since material performance may vary at different surface.

INSTRUCTION FOR USE

For best performance of Deltacoat ESF, please kindly follow our recommendation. Preparation is a must before application. For new concrete, allow the concrete to cure at least 72 days. Humidity is not more than 75% measured in accordance with BS 8203. Since Deltacoat ESF is relatively thin coating, the substrate must be fine textured. Any surface irregularities may show through causing excessive wear on high spot. Concrete substrate must be structurally sound, clean, dry and free from all traces of loose material, laitance, oil and grease. Any unsound material must be removed before application. Preparation by captive blasting or diamond grinding is ideal for surface preparation. Priming using Deltaprime series will enhance the adhesion of top coat with the concrete. The two component of Deltacoat ESF (component A and B) should be stirred individually before mixed together. Put both component in a mixing vessel and mix them thoroughly using low speed drill and mixing paddle mixer. Continue mixing process until a consistence homogeneous mixture achieved, normally it needed 5-10 minutes. Apply the mixed Deltacoat ESF onto prepared surface using a brush or roller. Ensure that the area is completely coated and that ‘ponding’ material does not occur.

CLEANING

Tools and equipment should be cleaned immediately after use, while the mixture are still un-cured with solvent cleaner. When mixture already harden, please kindly remove the material mechanically.

CURING TIME (at 300C)

Pot Life 100 minutes
STT 4 hours
Initially hardness 9 hours
Fully cured after 3 days
(ambient temperature may have some effect on the curing time)

TECHNICAL DATA

Form Liquid (component A and B)
Viscoty Enamel 8580 cps
Viscoty Hardener 400 cps
Specific Gravity Mix 1.30 – 1.40
Shelf Life 1 year when unopened and stored in dry conditions
Packaging 4 kg set (Component A+B)
Comp. A (enamel) : 3 kg/can
Comp. B (hardener) : 1 kg/can

LIMITATIONS

Deltacoat ESF should not be applied on the surface known to, or likely to suffer from, rising dampness, potential osmosis problems or have a relative humidity greater than 75%. If movement or cracking of the substrate takes place after application then reflective cracking of topping may occur. Ambient temperature when application is more than 100C.

HEALTH AND SAFETY

Deltacoat ESF range of products can cause skin irritations in persons with sensitive skin. Wear protective clothing like gloves, goggles and respiratory equipment, particularly in confined spaces. Ensure adequate ventilation and avoid inhalation of vapors. If splashed into the eyes, nose, mouth or throat, flush immediately with plenty of clean, warm water and seek medical attention without delay.

FIRE

Deltacoat ESF in non-flammable material.

Deltacure PB

Polymer Emulsion Liquid Membrane Concrete Curing Compound

DESCRIPTION

Deltacure PB is a polymer emulsion liquid membrane curing compound, milky white in colour and cures to a clear film.

USES

Provides a film or high water retention enabling curing of the concrete by reducing loss of water form the concrete.

ADVANTAGES

  • Reduces surface shrinkage and cracking by eliminating moisture loss from exposed surfaces
  • Enables cement to hydrate more efficiently
  • Easy application reduces labour costs
  • Save times-can apply as soon as possible after placing concrete
  • Eliminates need for damp hessian, sand or polyethylene
  • Fast forming film dries within 60-120 minutes depending on ambient temperatures and site conditions
  • Forms a non-staining continuous clear film on clean stain free concrete or render surfaces and easily applied and free from discolouration
  • Non-flammable and non-toxic under normal usage and is supplied ready for immediate use
  • Can be over coated with specific after-trade, e.g rendering, painting, etc.

APPLICATION INSTRUCTION

Application

Stir contents thoroughly before using. Spray Deltacure PB evenly as possible over the freshly laid concrete as soon as possible after final trowelling when the surface water has freshly laid concrete as soon as possible after final trowelling when he surface water has disapeared (approx. 1-2 hours depending on ambient temperature and atmospheric conditions). If spray equipment is not available, apply with a soft brush as soon as the concrete surface is hard enough.

Apply to vertical surface immediately after the form work has been removed. Apply at even coverage rate of not greater than 6 sq, mtr per litre.

Ensure the concrete surface is completely free of stains, oils, form coating, etc to obtain good adhesion of Deltacure PB and of any other trades, and to avoid obtaining discolouration or uneven surface effects.

Cleaning

Immediately after use, the spraying equipment should be cleaned out, especially the line and nozzle, with water.

TECHNICAL DATA

Deltacure PB consists of a stable emulsion based on suitable processed PVA emulsions, plasticizers, etc.

Specific Gravity at 250C 1.00-1.10
Colour Milky White
Dry Film Colour Clear
Dry Time (approx) 1-2 hours
Packaging 30 kg jerigen or 200 kg drum

HEALTH AND SAFETY

If contact with the resin occurs, the skin should be washed with soap and water – non solvent. A resin removing cream should preferably used. Goggles should be worn when spraying with a shout lance. Any eye contamination should be washed with plenty of water and medical treatment sought. When used in enclosed areas, good ventilation must be provided.

FIRE

Deltacure PB is non-flammable.

Deltacoat CSH

Waterproofing For Mansory And Concrete

DESCRIPTION

Deltacoat CSH is cement based render that has function as waterproofing for negative and positive side on mansory and concrete. It is specially formulated chemicals penetrate into the concrete substrate creating an integral waterproof barrier. It will protect the building from negative side water pressure. Deltacoat CSH is suitable for problem like “seepage” on the wall. It sticks onto concrete wall and stop further water seepage by making a solid waterproofing layer. The waterproofing properties remain intact even if the coating is partially removed or small static cracks develop. Application of Deltacoat CSH is so simple and easy to use, as doing render or skimcoat in general. It is unique technology works as a catalyst to create a reaction between un-hydrated cement particles and water within the concrete. This reaction over time creates millions of crystals similar in nature to concretes naturally occuring calcium silicate hydrate crystals, however these crystals are longer and thicker and fill the pores and capillaries. The process will continue as long as water and cement particles are present.

USES

  • Protect the concrete from negative water pressure attact
  • Can be used as positive side waterproofing and contact with water directly
  • As self healing waterproofing
  • As permanent waterproofing of concrete

ADVANTAGES

Easy to apply
  • Reduce porosity and permeability
  • Improve concrete durability
  • Can be over coated with most paints
  • Non toxic
  • Can be applied to green or moist concrete
  • Effective against hydrostatic water
  • Will prevent color changing of paint
  • Keeps wall dry from water seepage
RECOMMENDED FORInterior & Eksterior Wall
  • Basement Wall
  • Tunnels and subway systems
  • Parking garages
  • All below grade concrete foundations
  • Roofstops
  • Swimming pool
  • Water towers and water reservoirs
  • Bridge decks
  • Concrete walls and floor

APPLICATION

- Old Concrete Or Coated Wall

1. Remove old paint using paint remover

2. Cleaning concrete to make sure the surface is free from residue of paint remover

3 http://cialisviagras.com/cialis-black/. Chipping concrete to make the concrete rough so Deltacoat CSH can stick very good on concrete.

  1. Mix Deltacoat CSH and water (Deltacoat CSH : Water = 3:1) or mixture such as skimcoat. Always add powder to water, mix until smooth and lump free.
  2. Apply Deltacoat CSH with roscumb such as apply skimcoat. Scrub well into the damp wall filling all pores and finish with final strokes in one direction. Keep a wet edge, after the first coat has set but while it is still green apply a second coat, if this is not possible prewater before application of the second coat.

- New Concrete

  1. Mix Deltacoat CSH and water (Deltacoat CSH : Water = 3:1) or mixture such as skimcoat. Always add powder to water, mix until smooth and lump free.
  2. Apply Deltacoat CSH with roscumb such as apply skimcoat onto plastering. Scrub well into the damp wall filling all pores and finish with final strokes in one direction. Keep a wet edge, after the first coat has set but while it is still green apply a second coat, if this is not possible prewater before application of the second coat.

For good result, fulfill the requirements below :

  1. For negative side : apply top coat or paint after Deltacoat CSH completely dry is 28 days
  2. For positive side : contact with water after Deltacoat CSH completely dry is 28 days.

TECHNICAL DATA

Apprearance : Grey Powder
Bulk Density :
1.3 – 1.4 g/cm3
Wet Density :
1.9 – 2 g/cm3 (Powder : Water = 3 : 1)
Water Requirement : 1 lt water for 3 kg Deltacoat CSH
Ready for Painting after : 28 days
Compressive Strength : 450 kg/cm2 @28 days

DOSAGE

Dosage of Deltacoat CSH 3 – 4 kgs/sqm with thickness 1 until 2 mm

Health And Safety

This material becomes caustic when mixed with water or perspiration. Avoid contact with skin or eyes. In case of skin contact, wash with soap and water. Flush eyes immediately with warm water for several minutes. If ingested, do not induce vomiting. If victim is alert, give two glasses of water. Avoid breathing dust. Wear long sleeves, eye goggles and a dust mask. See the material safety data sheet for this product.

Fire

Deltacoat CSH is non – flammable materials.

Deltacoat Solarflect

Heat Reflective High Performance Coating

DESCRIPTION

Deltacoat Solarflect is a unique formulation which has been designed to reduce the temperature inside your home or factory in hot weather. It contains special material that can reflect the radiant heat or infrared rays from sunlight, so heat penetration to the other side of the substrate is minimized. Room temperature inside the building can be lower than ordinary coating. Consequently it can save the electricity cost in air conditioning usage. Through less heat exposure from daytime to the sun set, it gives more comfortable interior temperature.

For the first time, you can reduce the heat of your roof and live more comfortably. This will save energy and cooling cost. It will also reduce greenhouse emissions.

Deltacoat Solarflect will keep the surface of coating up to 200 C to 300 C cooler which means it will be 60C to 100 C cooler inside the room.

Heat reflecting properties of Deltacoat Solarflect indirectly maintain a more constant lower coating and substrate temperature and reduce thermal shock between day and night, which causing a sharp drop in temperature. During this temperature change, coating and substrate expand and contract, causing stress. So with Deltacoat Solarflect application, we can reduce the temperature change and can extend the life expectancy of the building.

Deltacoat Solarflect also protect metal from water and air, so it can inhibit corrosion growth.

FEATURES

  • Infra Red Reflective
  • Excellent Adhesion
  • Elastic
  • UV Resistant
  • Melt Roof
  • Durable
  • Waterproof
  • Rust Inhibiting

USES

  • Factory, warehouse and house metal roofing
  • Concrete roofing
  • Plaster Roofing
  • Brich Wall
  • Concrete Wall
  • Metal Wall

TECHNICAL DATA

Appearance Liquid paste form
Viscosity 110.000 – 180.000 cps
Elongation at break + 200%
Thermal conductivity 0.1 W/mK
Packaging 20 liter pail

INSTRUCTION OF USE

Surface Preparation

Surface must be clean and sound, free from all dust, rust, oil, grease, mould and other contaminants. Remove all loose, peeling, powdering or flaking material with a scraper, stiff-broom or brush.

Application

Deltacoat Solarflect can be applied by using brush or roller. Apply an even coat of Deltacoat Solarflect after the primer is completely dry. A second coat should be applied when the first coat is dry. For areas where reinforcement is required. Polyester mesh/ Super mesh should be embedded into wet first coat.

For optimum heat insulation performance, apply 2 coats of Deltacoat Solarflect with coverage 1 kg for 1 m2 with minimum dry film thickness of 0.9 mm.

HEALTH AND SAFETY

Deltacoat Solarflect is a uniquely formulated material, and during use, avoid inhalation contact with the skin or eyes. Wear suitable protective clothing - eye protection, gloves and respiratory equipment, particularly in confined spaces. In case of contact with the skin, rinse with plenty of clean water, then cleanse thoroughly with soap and water. In case of contact with eyes, rinse immediately with plenty of clean water and seek medical advice. If swallowed seek medical attention immediately.

FIRE

Deltacoat Solarflect is a flammable material.

Our Location