+62-21-344 2919      +62-21-3511 428      +62-811-9119-611   
    deltacrete@gmail.com      Senin - Jumat 9.00 - 17.00

Deltafloor SL2000

Heavy Duty Self Levelling Epoxy Flooring System

DESCRIPTION

A three-component epoxy resin flooring system that applicable for a seamless, self levelling, self smoothing requirement. Made from solvent free epoxy resin system and selected graded fillers. Deltafloor SL2000 exhibits excellent seamless smooth surfaces with an excellent resistance to abrasion. A wide range of colour is also provided to ensure the customer need.

USES

Deltafloor SL2000 is recommended to areas where a heavy level of resistance to abrasion is required whereas a high level of aesthetic is also an essential factor. Deltafloor SL2000 is recommended for use in floor of laboratories, clean rooms and other medical facilities such as in pharmaceutical, cosmetic, and food industries.

ADVANTAGES

  • High resistance to both chemical attack and abrasion.
  • Easy to clean and maintain,
  • Hygienic,
  • Chemical resistance and have aesthetic state of art.

CONSUMPTION

Deltafloor SL2000 consumption is 3500 gram/m2 for 2 mm thickness. To be noted some preparation using Deltaprime TC has to be done due to have a good result. Please kindly contact DELTACRETE to have appropriate technical assistance for the recommended thickness since material performance may vary at different surface.

INSTRUCTION FOR USE

Preparation:

In order to have a good bonding to concrete substrate, for new concrete, allow the concrete to cure at least 28 days. Humidity is not more than 75% measured in accordance with BS 8203. Concrete substrate must be structurally sound, clean, dry and free from all traces of loose material, laitance, oil and grease. Any unsound material must be removed before application. Preparation by captive blasting or diamond grinding is ideal for surface preparation. Priming using Deltaprime Series will enhance the adhesion of top coat with the concrete.

Even though Deltafloor SL2000 is able to cover up some high spot of the concrete surfaces, it is recommended to grind and patch the surface irregularities.

Mixing:

Deltafloor Color Pot should be mixed thoroughly with component A (enamel) first before further action. The two component of Deltafloor SL2000 (component A and B) should be stirred individually before mixed together. Put both component in a mixing vessel and mix them thoroughly using low speed drill and mixing paddle mixer. Continue to pour the filler to the mixture, mix them through until a consistence homogeneous mixture achieved, normally it needed 3-5 minutes.

Placing:

Please border your application location using masking tape and not to remove it before Deltafloor SL2000 fully cured, Pour the mixture right after mixing onto the concrete surface, An suitable notched trowel is needed to spread the mixture onto the floor, Roll the Deltafloor SL2000 with spiked roller to released the entrapped air and remove any trowel mark. Do not step on the top Deltafloor SL2000 40 minutes after application, it may leave unwanted mark at the surface.

CLEANING

Tools and equipment should be cleaned immediately after use, while the mixture are still un-cured with solvent cleaner. When mixture already harden, please kindly remove the material mechanically

TECHNICAL DATA

Form Component A + B - Liquid; Component C – Powder
Mix Density 1.62 kg/litre
Compressive Strength
7 days ( BS 6319)
55 N/mm2
Flexural Strength
7 days ( BS 6319)
35 N/mm2
Pot Life 40 mins @ 300C
Initially hardness 24 hours
Fully cured after 7 days
Shelf Life< 1 year when unopened and stored in dry conditions
Packaging 19.5 kg/set ( A + B + Color Pot + C )
Comp. A (Enamel) : 8.40 kg/set
Comp. B (Hardener) : 2.75 kg/set
Comp. C (Filler) : 8 kg/set
Color pot : 0.45 kg/set

LIMITATIONS

Deltafloor SL2000 should not applied on the surface known to, or likely to suffer from, rising dampness, potential osmosis problems or have a relative humidity greater than 75%. If movement or cracking of the substrate takes place after application then reflective cracking of topping may occur. Ambient temperature when application is more than 100C.

HEALTH AND SAFETY

Deltafoor range of products can cause skin irritations in persons with sensitive skin. Wear protective clothing like gloves, goggles and respiratory equipment, particularly in confined spaces. Ensure adequate ventilation and avoid inhalation of vapors. If splashed into the eyes, nose, mouth or throat, flush immediately with plenty of clean, warm water and seek medical attention without delay.

FIRE

Deltafloor SL2000 is flammable material. Keep it away from source of ignition. Smoking is not allowed during material application. In the event of fire, extinguish with CO2 or foam.

Our Location

PT. Deltacretindo Wira Mandiri
  JL. Pintu Air IV No. 41A
  Jakarta, Indonesia 10710
  +62-21-344 2919
  +62-21-3511 428
  +62-811-9119-611
   :  deltacrete@gmail.com

haki cm